ID | Description |
---|---|
MRE-673 |
Bentley MicroStation 64-bit is now supported. |
MRE-1697 | Files are now imported into the vault as a single batch by the link when an export is performed in Revit. |
MRE-2423 | The performance of opening Autodesk Inventor assemblies with the Meridian Web Client in Remote mode has been improved. |
MRE-2482 | Reference type names created in the destination vault after SolidWorks drawings are imported from a package are now different than the names shown in the source vault. |
MRE-2794 |
The Revit link now behaves correctly when the ReleaseSynchronizedCentral settings is set to 1 and UseUnderChangeToSychronizeCentral setting is 0. |
MRE-2821 | Bentley MicroStation V8i SELECTseries 4 is now supported. |
MRE-2837 |
The AutoCAD link supports a new configuration setting DateTimeConverter that specifies the name of an existing VBScript function to call to convert date/time attribute values that do not contain time unit separators, for example, ddMMMyyyy. |
MRE-2903 | The AutoCAD link supports a new configuration setting SupportWizards that, when set to 1 and a new drawing is saved in the vault from AutoCAD, causes the AutoCAD link to synchronize the title block from the vault first before the document properties are set from the linked drawing attribute values. This ensures that the title block attributes are set to the values that were entered in property wizard pages and that the document properties are not overwritten from possibly different attribute values. |
MRE-2972 | A new setting MinimumAttachmentSizeKB has been added to the email link. It can be configured to specify the minimum size (in KB) of an email message attachment before it will be saved in the vault with the message. This setting is intended to filter out irrelevant attachments such as message signature images. |
MRE-3100 |
SolidWorks title block updates now work correctly if custom properties are set to write-only (WO flag). |
MRE-3126 | Synchronizing properties to the document file now works correctly for .DOC files if custom properties are set to write-only (WO flag). |
MRE-3181 |
The Title Blocks property page captions are now configurable in the Revit link. A document type can also be specified to which the captions are applied. |
MRE-3192 |
Saving documents from Outlook with the link in Remote mode no longer causes the error No such interface supported. |
MRE-3318, MRE-3807 |
Autodesk AutoCAD 2017 SP1, AutoCAD P&ID 2017 SP1, AutoCAD Plant 3D 2017 SP1, and AutoCAD Plant 3D 2017.1 are now supported. |
MRE-3413 | The Office link now shows BlueCielo Meridian Enterprise as a place on the Open and Save As pages in Office 2013 and later applications. The most recently used vault folders are also listed for convenience. A default vault must be set for the Set Default Context option in Application Integration to initialize browsing and prevent an error. |
MRE-3459 | The AutoCAD links and the BlueCielo viewer now use Autodesk RealDWG 2017 SP1 for file access. |
MRE-3530 | Bentley MicroStation 10.00 (V10) is now supported. |
MRE-3718 | Autodesk AutoCAD 2017.1 is now supported. |
MRE-3769 | Autodesk Inventor Cable and Harness files and components are now saved correctly in the vault by the Inventor link. |
For more information, see BlueCielo Meridian Enterprise Configuration Guide and BlueCielo Meridian Enterprise User’s Guide.